• Fan Garden Police Quarters


New Buildings V1.2
Final Gold

Overall Score
Site Aspects
Materials Aspects
Energy Use
Water Use
Indoor Enviro. Quality
Credit(s)    Innovations and Additions

In the Junior Police Officer Married Quarter, 100% of roof area adopt greenery and high SRI material to reduce surface temperature in summer, as compare with bare asphalt or concrete rooftop. 100% of all timber and composite timber products used in the project including door, flooring wardrobes etc. are from sustainable sources.

Green Features

Site Aspects

  • 20% of site coverage of greenery
  • 100% of roof area are adopted with greenery and high SRI materials of at least 78
  • Environmental management to minimize air, noise and water pollution during construction
  • Computer Fluid Dynamics (CFD) simulation study is conducted to demonstrate no pedestrian areas will be subject to excessive wind velocities. Different options are also compared using CFD to demonstrate the optimal option is selected

Materials Aspects

  • Over 66% of the total CFA applying modular design
  • 100% of all timber and composite timber products used in the project including door, flooring, wardrobes and cabinets are from sustainable sources
  • 25% of regionally manufactured materials within 800km from the project site

Energy Use

  • Low solar irradiance (119.929 kWhr/m2) of building facade
  • Adoption of energy efficient building envelope to achieve a lower OTTV (21.05 W/m2)
  • 21% of habitable areas comply with the natural ventilation requirements
  • High efficiency lighting and lifts to reduce annual energy consumption reduction
  • Separate metering to monitor landlord lighting and power, lift, P&D, AC and small power 

Water Use

  • 40% of estimated annual water saving from the use of water efficient devices
  • 52% of reduction in annual sewage volume from the use of water efficient devices

Indoor Environmental Quality

  • Building amenities to enhance the quality and functionality of the building
  • Enhanced designs for barrier free access
  • 30% increased ventilation of ASHRAE 62.1-2007
  • At least 80% of floor area in all normally occupied spaces are adequately lit with at least 1% of average daylight factor
  • Good class Indoor Air Quality (IAQ)

Innovations and Additions

  • Twin tank for potable and flushing water supply
  • 100% sustainable timber products


Project Details

Completion Year 2021
Number of Blocks 5
Number of Storeys 29 to 31
Type Residential
Total Site Area 13850

Project Team

Project Developer / Owner Hong Kong Police Force, HKSAR Government
Project Manager Architectural Services Department
Architect Chung Wah Nan Architects Limited
Sustainable Design Consultant Allied Environmental Consultants Limited
Environmental Consultant Allied Environmental Consultants Limited
C&S Engineer Meinhardt (C&S) Limited
M&E Engineer Meinhardt (M&E) Limited
Landscape Architect Kenneth Ng & Associates (HK) Limited
Quantity Surveyor C.S. Toh & Sons & Associates Limited
Acoustic Consultant Allied Environmental Consultants Limited
Main Contractor Shui On Construction Company Limited
Back

  • 1/F, Jockey Club Environmental Building, 77 Tat Chee Avenue, Kowloon Tong, Hong Kong.
  • +852 3994 8888
  • [email protected]

  • © 2024 Hong Kong Green Building Council Limited. All rights reserved.
  • Disclaimer

Stay connected:




© 2024 Hong Kong Green Building Council Limited. All rights reserved.
Disclaimer